Bs 6364 standard pdf

Applies to the size range dn 15 to the maximum size in the applicable. Bs 6364 valves for cryogenic service valve leak scribd. Specification for copper alloy globe, globe stop and check. Thermosetting insulated, armoured, fireresistant cables of rated voltage 6001 000 v for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Inspection categories and verification procedure for testing at elevated. Valves made to bs 1873 usually dual conform to ansi b16. Technical advice bs1504 concrete repair bs 1504 the protection and repair of concrete structures has now been fully implemented throughout the eu. Rev 00 716 the triad series 90c93c ball valves are available with the v ball. Also available with bs iso 200001 a4 5492 inc standard hardcopy and pdf 2011 isbn 978 0 580 72850 1 978 0 580 76551 3 inc standard 01240 inc standard published by bsi price. To enhance and maintain our high standards of valve design and production testing, we operate with stringent cryogenic testing programmes in our test facility. Gate globe valves are tested as per bs 6364 for cryogenic service. Requirements for carbon, low alloy, corrosion resisting, heat resisting and high alloy steel castings for pressure purposes including chemical composition, mechanical properties at room and elevated temperatures, low temperature impact properties, etc. The above test had been carried out at kancheepuram plant of valves limited, satisfactorily witnessed by the undersigned surveyor of tuv india pvt. Bs 1982 tubes for use in scaffolding tube solution.

Bs 6364 valves for cryogenic service published by bsi on february 29, 1984 specifies requirements supplementary to those in the applicable valve product standards when the valves are used for. Aug 18, 2017 codes, standards and recommended practices by theprocesspiping published august 18, 2017 updated october 29, 2017 standardization is the process of implementing and developing technical documents based on the consensus of different parties that include firms, users, interest groups, standards organizations and governments. Cryogenic service leak rates comply with standards such as bs 6364, iso 1626 and en 12567. There is no api standard for globe valves, however api 600, api. Ansifci 7022005 valve leakage classifications supersedes ansi b16. Circular flanges for pipes, valves, fittings and accessories, pn designated. Cryogenic valves api 598 iso 5208, bs 6364 control valves fci 702, isas75 pressure relief valves api 527, asme ptc 25 iso 5208 en 122661 supersedes bs 6755. The vacuum chamber allows accurate process simulation that is not possible with the industry standard test apparatus. All bsi british standards available online in electronic and print formats. Similarly ball valves manufactured to api 608 may be specified as tested to api 6d.

The preparation of this british standard was entrusted by the. The selection and testing of valves for lng applications sigtto. Vanessa, the triple offset valve represents an important step forward in cryogenic valve applications compared to any other valve design. Any glazing within a red shaded area must comply with bs 6262. This covers plain, boss, integrally cast or forged, and welding neck type flanges, in ten tables. The above test had been carried out at kancheepuram plant of valves limited. Cryogenic test service in compliance with bs 6364 standard is available inhouse upon request. The tests are carried out in a cryogenic bath or inline under pressure according to standard requirements of international standards such as bs 6364. Valves with ltcs material, test was conducted at 46. Bs 6364, and is made with materials selected carefully to match pipe speci. The accuracy of such a claim is therefore solely the manufacturers responsibility. Once you have purchased your british standards download you will be entitled to download one copy of each british standards pdf onto a single computer.

Design, specifications and future challenges for cryogenic valves. Standard specification for alloysteel and stainless steel bolting materials for high temperature or high pressure service and other special purpose applications 8 bs 6364. For the first time in the uk there are now standards for products to be used as well as for the design, testing and for site application. Find the most uptodate version of bs 6364 at engineering360. There are certain british standards referred by indian manufacturers for piping and valves.

Bs 6364 cryogenic test certified cryogenic extension mss sp42012 face to face complies with asme b16. Applies to the size range dn 15 to the maximum size in the applicable product standards and in the temperature range of 50c to 196c. Valves made to bs 1873 usually dual conform to ansi. Bs 6364 valves for cryogenic service free download as pdf file. Design, specifications and future challenges for cryogenic. With more than 15 years of experience of testing valves designed for low temperature and cryogenic purposes, itis can offer customers the benefit of considerable practical expertise in testing and problemsolving.

This british standard sets out the specifications and required tests for single core and three core armoured cables with thermosetting insulation with a voltage rating ranging from 3. Valvtechnologies cryogenic laboratory uses a proprietary vacuum test chamber as well as the more common immersion testing tanks. Find the most uptodate version of bs 1504 at engineering360. For example, bs 2080 british standard for face to face or end to end dimensions of valves is identical to ansiasme b16. Bs6387 covers fire resistant cables with a voltage rating of 300500v and 450750v. It also covers mineralinsulated cables manufactured in accordance with bs6207. C and austenitic stainless steel valves were tested at 196. Specifies requirements supplementary to those in the applicable valve product standards when the valves are used for cryogenic service. Comparison of contemporary cryogenic valve standards, valve. Bs 6364 mss sp4 iso 289211 parent standard british standards asme b16. Reviewe bs 6364 valves for cryogenic service free download as pdf file. Reviewe standard about cryogenic testing of valves that i know is bs 6364. Valvtechnologies cryogenic laboratory uses a proprietary vacuum test chamber as well as the more common immersion testing. Bsi bs 6364 valves for cryogenic service engineering360.

The uk participation in its preparation was entrusted to technical committee pse181, industrial valves, steam traps, actuators and safety devices against excessive pressure valves basic standards. The habonim standard bonnet length design complies with. An example of a bs standard that cannot be purchased as a downloadable british standard is bs 5252f. Additional inhouse optional tests are listed in the build. The uk participation in its preparation was entrusted to.

Codes, standards and recommended practices the process piping. Bs 6364 complete document 84th edition, april 30, 91. Additional inhouse optional tests are listed in the build your cryogenic valve code section of this catalog. Bsis essential guide to books, cdroms and online products. Requirements for carbon, low alloy, corrosion resisting, heat resisting and high alloy steel castings for pressure purposes including. Although bs 10 is obsolescent, it remains in use for the dimensions. The preparation of this british standard was entrusted by the mechanical engineering standards committee mee to technical committee mee191 upon which the following bodies were represented. As standard, the habonim cryogenic valve design is firesafe. The vacuum chamber allows accurate process simulation that is not possible with the industrystandard test apparatus. An example of a downloadable british standard is bs en iso 9001.

Bs en 12266 guide on leak rate 2015 british standard bs en 122661. Cryogenic valve standards that are used in the valve industry include. Standards commonly used in the uk joining industry the. We offer a comprehensive range of medium voltage mv cables manufactured to various british, european and international standards, including bs6622.

398 1040 392 1220 485 1448 759 983 533 935 1028 948 1356 208 1569 1117 514 898 1099 823 1471 98 1560 803 1255 57 158 1127 1288 820 931 513